A detailed analysis is made in this problem solving
guide for common problems faced in Packaging Flexo
press room. A brief description is given of each dilemma alongwith
the possible causes and remedies. If you still have more questions
, please use our Enquiry section to ask our experts.
Streaks?
CAUSE
|
REMEDY
|
1.
Foreign Particle under blade |
- Reduce blade
pressure under blade
- Install ink
filters in ink system
- Install magnets
in ink system
- Change the
doctor blade
|
2.
Cut in doctor blade |
- Install ink
filters
- Change doctor
the blade
- Check roughness
of anilox roller
- Check new
blade tip for damage (if small, polish with #600 emery
paper)
|
3.Abrasive
ink and/or solvents |
- Use STAINLESS
STEEL doctor blade
- Use different
pigments
- Check pH balance
of ink (water-based)
|
Uneven Ink Metering ?
CAUSE |
REMEDY |
1.
Blades is wavy |
- Clean the
doctor blade holder and remount blade
- Check blade
holder for damage
- Tighten bolts
from center out alternating sides
- Replace missing
bolts if any
- Provide even
tensioning of bolts on holder by using a torque wrench
- Make sure
blade is not too long for holder
- Check end
seal placement
|
2.
Alignment |
- ensure centerline
of chamber is parallel to center line of anilox roller
- Make sure
both the blades in the chamber contact the anilox
roller at the same time
- Ensure uniform
extension from holder
|
3.
Vibration |
- Blade chatter- blade angle too steep
- Gear vibration from press
- Bounce from printing plate, fix the plate uniformly
|
Excessive Anilox Wear ?
CAUSE |
REMEDY |
1.
Extra pressure on doctor blade |
- Look for the
reasons why excessive pressure is needed and
correct
- Install mechanical
units to ensure the chamber does not contact
anilox roller
- Metal fillings
(silvers) from the blade tip. (Excessive pressure
causes wiping by back of blade rather than the tip.
The blade tip becomes thin and wears through, releasing
silvers in inking system. This can damage the anilox.)
|
2.
Contact area too large |
- Use correct
width doctor blade (check with holder manufacturer
for correct size)
- Use reduced
thickness blade tip
- Reduced blade
thickness if using straight steel
- Check blade
angles
|
3.
Poor steel quality |
- Analyse steel
for purity
- Check for
excessive roughness on blade tip ( use fine polishing
paper to correct)
- Try alternative
blade materials (check with SUREPRINT to correctly match
blade to application)
|
Excessive Ink Film Thickness ?
CAUSE |
REMEDY |
1.Contact
area too large for cell count |
- Use pre-ground
lamella blade to reduce contact area
- Incorrect
blade angle
- Use thinner
blades
|
2.Cell
volume or cell count of anilox not matched to line screen
count of plate |
- Guideline: Cell count should be 4-5 times that of plate
|
Leaking Chamber ?
CAUSE |
REMEDY |
1.
Incorrect chamber alignment |
- Ensure chamber is parallel to anilox roller and both top and bottom
blades are contacting anilox roller at the same time
|
2.Incorrect
end seals or incorrect setting |
- Check with
holder manufacturer for correct material and
dimensions
- Check blade
settings (ensure blade extension is correct to match
cut on end seal)
|
3.Blade
is wavy |
- Improper seating
of blade in holder allows ink to escape holder
- Poor condition
of holder
- Missing or
worn bolts in holder assembly
|
4.Re-doctoring
of ink from containment blade |
- Reduce excessive
blade pressure
- Correct ink
viscosity
- Incorrect
containment blade for press holder or anilox
|
|